Heat capacity

From SklogWiki
Revision as of 15:44, 8 July 2008 by Carl McBride (talk | contribs) (Changed some equals for definitions.)
Jump to navigation Jump to search

From the first law of thermodynamics one has

δQ=dU+pdV

where Q is the heat, U is the internal energy, p is the pressure and V is the volume. The heat capacity is given by the differential of the heat with respect to the temperature,

C:=δQ∂T

At constant volume

At constant volume (denoted by the subscript V),

CV:=δQ∂T|V=∂U∂T|V


At constant pressure

At constant pressure (denoted by the subscript p),

Cp:=δQ∂T|p=∂U∂T|p+p∂V∂T|p


The difference between the heat capacity at constant pressure and the heat capacity at constant volume is given by

Cp−CV=(p+∂U∂V|T)∂V∂T|p